§ 192.471 External corrosion control: Test leads.

49 CFR 192.471

Citation49 CFR 192.471
CorpusDaily eCFR
Displayed edition2026-10-01
Last updated2026-10-01

§ 192.471 External corrosion control: Test leads.

(a) Each test lead wire must be connected to the pipeline so as to remain mechanically secure and electrically conductive.

(b) Each test lead wire must be attached to the pipeline so as to minimize stress concentration on the pipe.

(c) Each bared test lead wire and bared metallic area at point of connection to the pipeline must be coated with an electrical insulating material compatible with the pipe coating and the insulation on the wire.

Authority30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et. seq., and 49 CFR 1.97.
Source35 FR 13257, Aug. 19, 1970, unless otherwise noted.