Title 49

PART 236 SUBPART A

Subpart A - Rules and Instructions: All Systems

49:4.1.1.1.30.1.107SUBJGRP 107
General
49:4.1.1.1.30.1.107.1SECTION 236.1
   236.1 Plans, where kept.
49:4.1.1.1.30.1.107.2SECTION 236.2
   236.2 Grounds.
49:4.1.1.1.30.1.107.3SECTION 236.3
   236.3 Locking of signal apparatus housings.
49:4.1.1.1.30.1.107.4SECTION 236.4
   236.4 Interference with normal functioning of device.
49:4.1.1.1.30.1.107.5SECTION 236.5
   236.5 Design of control circuits on closed circuit principle.
49:4.1.1.1.30.1.107.6SECTION 236.6
   236.6 Hand-operated switch equipped with switch circuit controller.
49:4.1.1.1.30.1.107.7SECTION 236.7
   236.7 Circuit controller operated by switch-and-lock movement.
49:4.1.1.1.30.1.107.8SECTION 236.8
   236.8 Operating characteristics of electromagnetic, electronic, or electrical apparatus.
49:4.1.1.1.30.1.107.9SECTION 236.9
   236.9 Selection of circuits through indicating or annunciating instruments.
49:4.1.1.1.30.1.107.10SECTION 236.10
   236.10 Electric locks, force drop type; where required.
49:4.1.1.1.30.1.107.11SECTION 236.11
   236.11 Adjustment, repair, or replacement of component.
49:4.1.1.1.30.1.107.12SECTION 236.12
   236.12 Spring switch signal protection; where required.
49:4.1.1.1.30.1.107.13SECTION 236.13
   236.13 Spring switch; selection of signal control circuits through circuit controller.
49:4.1.1.1.30.1.107.14SECTION 236.14
   236.14 Spring switch signal protection; requirements.
49:4.1.1.1.30.1.107.15SECTION 236.15
   236.15 Timetable instructions.
49:4.1.1.1.30.1.107.16SECTION 236.16
   236.16 Electric lock, main track releasing circuit.
49:4.1.1.1.30.1.107.17SECTION 236.17
   236.17 Pipe for operating connections, requirements.
49:4.1.1.1.30.1.107.18SECTION 236.18
   236.18 Software management control plan.
49:4.1.1.1.30.1.108SUBJGRP 108
Roadway Signals and Cab Signals
49:4.1.1.1.30.1.108.19SECTION 236.21
   236.21 Location of roadway signals.
49:4.1.1.1.30.1.108.20SECTION 236.22
   236.22 Semaphore signal arm; clearance to other objects.
49:4.1.1.1.30.1.108.21SECTION 236.23
   236.23 Aspects and indications.
49:4.1.1.1.30.1.108.22SECTION 236.24
   236.24 Spacing of roadway signals.
49:4.1.1.1.30.1.108.23SECTION 236.25
   236.25 [Reserved]
49:4.1.1.1.30.1.108.24SECTION 236.26
   236.26 Buffing device, maintenance.
49:4.1.1.1.30.1.109SUBJGRP 109
Track Circuits
49:4.1.1.1.30.1.109.25SECTION 236.51
   236.51 Track circuit requirements.
49:4.1.1.1.30.1.109.26SECTION 236.52
   236.52 Relayed cut-section.
49:4.1.1.1.30.1.109.27SECTION 236.53
   236.53 Track circuit feed at grade crossing.
49:4.1.1.1.30.1.109.28SECTION 236.54
   236.54 Minimum length of track circuit.
49:4.1.1.1.30.1.109.29SECTION 236.55
   236.55 Dead section; maximum length.
49:4.1.1.1.30.1.109.30SECTION 236.56
   236.56 Shunting sensitivity.
49:4.1.1.1.30.1.109.31SECTION 236.57
   236.57 Shunt and fouling wires.
49:4.1.1.1.30.1.109.32SECTION 236.58
   236.58 Turnout, fouling section.
49:4.1.1.1.30.1.109.33SECTION 236.59
   236.59 Insulated rail joints.
49:4.1.1.1.30.1.109.34SECTION 236.60
   236.60 Switch shunting circuit; use restricted.
49:4.1.1.1.30.1.110SUBJGRP 110
Wires and Cables
49:4.1.1.1.30.1.110.35SECTION 236.71
   236.71 Signal wires on pole line and aerial cable.
49:4.1.1.1.30.1.110.36SECTION 236.72
   236.72 [Reserved]
49:4.1.1.1.30.1.110.37SECTION 236.73
   236.73 Open-wire transmission line; clearance to other circuits.
49:4.1.1.1.30.1.110.38SECTION 236.74
   236.74 Protection of insulated wire; splice in underground wire.
49:4.1.1.1.30.1.110.39SECTION 236.75
   236.75 [Reserved]
49:4.1.1.1.30.1.110.40SECTION 236.76
   236.76 Tagging of wires and interference of wires or tags with signal apparatus.
49:4.1.1.1.30.1.111SUBJGRP 111
Inspections and Tests; All Systems
49:4.1.1.1.30.1.111.41SECTION 236.101
   236.101 Purpose of inspection and tests; removal from service of relay or device failing to meet test requirements.
49:4.1.1.1.30.1.111.42SECTION 236.102
   236.102 Semaphore or searchlight signal mechanism.
49:4.1.1.1.30.1.111.43SECTION 236.103
   236.103 Switch circuit controller or point detector.
49:4.1.1.1.30.1.111.44SECTION 236.104
   236.104 Shunt fouling circuit.
49:4.1.1.1.30.1.111.45SECTION 236.105
   236.105 Electric lock.
49:4.1.1.1.30.1.111.46SECTION 236.106
   236.106 Relays.
49:4.1.1.1.30.1.111.47SECTION 236.107
   236.107 Ground tests.
49:4.1.1.1.30.1.111.48SECTION 236.108
   236.108 Insulation resistance tests, wires in trunking and cables.
49:4.1.1.1.30.1.111.49SECTION 236.109
   236.109 Time releases, timing relays and timing devices.
49:4.1.1.1.30.1.111.50SECTION 236.110
   236.110 Results of tests.