Appendix B to Part 564 - Information to be Submitted for Long Life Replaceable Light Sources of Limited Definition
49:6.1.2.3.32.0.7.6.26 : Appendix B
Appendix B to Part 564 - Information to be Submitted for Long Life
Replaceable Light Sources of Limited Definition I. Filament or
Discharge Arc Position Dimensions and Tolerances Using Either
Direct Filament or Discharge Arc Dimensions or the Three
Dimensional Filament Discharge Arc Tolerance Box
A. Lower beam filament or discharge arc dimensions or filament
or discharge arc tolerance box dimensions and relation of these to
the bulb base reference plane and centerline.
1. Axial location of the filament or discharge arc centerline or
the filament or discharge arc tolerance box relative to the bulb
base reference plane.
2. Vertical location of the filament or discharge arc centerline
or the filament or discharge arc tolerance box relative to the bulb
base centerline.
3. Transverse location of the filament or discharge arc
centerline or the filament or discharge arc tolerance box relative
to the bulb base centerline.
4. Filament or discharge arc tolerance box dimensions, if
used.
B. Upper beam filament or discharge arc dimensions or the
filament or discharge arc tolerance box dimensions and relation of
these to the bulb base reference plane and centerline.
1. Axial location of the filament or discharge arc centerline or
the filament or discharge arc tolerance box relative to the bulb
base reference plane.
2. Vertical location of the filament or discharge arc centerline
or the filament or discharge arc tolerance box relative to the bulb
base centerline.
3. Transverse location of the filament or discharge arc
centerline or the filament or discharge arc tolerance box relative
to the bulb base centerline.
4. Filament or discharge arc tolerance box dimensions, if
used.
C. If the replaceable light source has both a lower beam and
upper beam filament or discharge arc, the dimensional relationship
between the two filament or discharge arc centerlines or the
filament or discharge arc tolerance boxes may be provided instead
of referencing the upper beam filament or discharge arc centerline
or filament or discharge arc tolerance box to the bulb base
centerline or reference plane.
D. For a light source using excited gas mixtures as a filament,
necessary fiducial information and specifications including
electrode position dimensions, and tolerance information that
provide similar location and characteristics information required
by paragraphs A, B, and C of this section I for light sources using
a resistive type filament.
II. Bulb Base Interchangeability Dimensions and Tolerance
A. Angular locations, diameters, key/keyway sizes, and any other
interchangeability dimensions for indexing the bulb base in the
bulb holder.
B. Diameter, width, depth, and surface finish of seal groove,
surface, or other pertinent sealing features.
C. Diameter of the bulb base at the interface of the base and
its perpendicular reference surface.
D. Dimensions of features related to retention of the bulb base
in the bulb holder such as tabs, keys, keyways, surface, etc.
III. Bulb Holder Interchangeability Dimensions and Tolerances
A. Mating angular locations, diameters, key/keyway sizes, any
other interchangeability dimensions for indexing the bulb base in
the bulb holder.
B. Mating diameter, width, depth, and surface, or other
pertinent sealing features.
C. Mating diameter of the bulb holder at the interface of the
bulb base aperture and its perpendicular reference surface.
D. Mating dimensions of features related to retention of the
bulb base in the bulb holder such as tabs, keys, keyways, surface,
or any other characteristics necessary for mating dimensions.
IV. Electrical Specifications for Each Light Source That Operates
With a Ballast and Rated Life of the Light Source/Ballast
Combination
A. Maximum power (in watts).
B. Luminous Flux (in lumens).
C. Rated laboratory life of the light source/ballast combination
(not less than 2,000 hours).
V. Applicable to Light Sources That Operate With a Source Voltage
Other Than 12.8 Volts Direct Current, and When a Proprietary
Ballast Must Be Used With the Light Source
A. Manufacturer's part number for the ballast.
B. Any other characteristics necessary for system operation.
VI. Bulb Markings/Designation - ANSI NUMBER, ECE IDENTIFIER,
MANUFACTURER'S PART NUMBER, INDIVIDUAL OR IN ANY COMBINATION VII.
All Other Identification, Dimensions or Performance Specifications
Necessary for Replaceability or Systems Test Not Listed in Sections
I Through VI