| All sewage sludge incineration units |
| Combustion chamber operating temperature (not required if afterburner temperature is monitored) | Minimum combustion chamber operating temperature or afterburner temperature | Continuous | Every 15 minutes | 12-hour block. |
| Fugitive emissions from ash handling | Site-specific operating requirements | Not applicable | Not applicable | Not applicable. |
| Scrubber |
| Pressure drop across each wet scrubber | Minimum pressure drop | Continuous | Every 15 minutes | 12-hour block. |
| Scrubber liquid flow rate | Minimum flow rate | Continuous | Every 15 minutes | 12-hour block. |
| Scrubber liquid pH | Minimum pH | Continuous | Every 15 minutes | 3-hour block. |
| Fabric Filter |
| Alarm time of the bag leak detection system alarm | Maximum alarm time of the bag leak detection system alarm (this operating limit is provided in § 60.4850 and is not established on a site-specific basis) |
| Electrostatic precipitator |
| Secondary voltage of the electrostatic precipitator collection plates | Minimum power input to the electrostatic precipitator collection plates | Continuous | Hourly | 12-hour block. |
| Secondary amperage of the electrostatic precipitator collection plates | | | | |
| Effluent water flow rate at the outlet of the electrostatic precipitator | Minimum effluent water flow rate at the outlet of the electrostatic precipitator | Hourly | Hourly | 12-hour block. |
| Activated carbon injection |
| Mercury sorbent injection rate | Minimum mercury sorbent injection rate | Hourly | Hourly | 12-hour block. |
| Dioxin/furan sorbent injection rate | Minimum dioxin/furan sorbent injection rate. | | | |
| Carrier gas flow rate or carrier gas pressure drop | Minimum carrier gas flow rate or minimum carrier gas pressure drop | Continuous | Every 15 minutes | 12-hour block. |
| Afterburner |
| Temperature of the afterburner combustion chamber | Minimum temperature of the afterburner combustion chamber | Continuous | Every 15 minutes | 12-hour block.
|