Title 40
PART 1065 SUBPART C
Subpart C - Measurement Instruments
- 42 U.S.C. 7401-7671q.
- 70 FR 40516, July 13, 2005, unless otherwise noted.
40:37.0.1.1.2.3.15 | SUBJGRP 15 | Measurement of Engine Parameters and Ambient Conditions | |
40:37.0.1.1.2.3.15.1 | SECTION 1065.201 | 1065.201 Overview and general provisions. | |
40:37.0.1.1.2.3.15.2 | SECTION 1065.202 | 1065.202 Data updating, recording, and control. | |
40:37.0.1.1.2.3.15.3 | SECTION 1065.205 | 1065.205 Performance specifications for measurement instruments. | |
40:37.0.1.1.2.3.15.4 | SECTION 1065.210 | 1065.210 Work input and output sensors. | |
40:37.0.1.1.2.3.15.5 | SECTION 1065.215 | 1065.215 Pressure transducers, temperature sensors, and dewpoint sensors. | |
40:37.0.1.1.2.3.16 | SUBJGRP 16 | Flow-Related Measurements | |
40:37.0.1.1.2.3.16.6 | SECTION 1065.220 | 1065.220 Fuel flow meter. | |
40:37.0.1.1.2.3.16.7 | SECTION 1065.225 | 1065.225 Intake-air flow meter. | |
40:37.0.1.1.2.3.16.8 | SECTION 1065.230 | 1065.230 Raw exhaust flow meter. | |
40:37.0.1.1.2.3.16.9 | SECTION 1065.240 | 1065.240 Dilution air and diluted exhaust flow meters. | |
40:37.0.1.1.2.3.16.10 | SECTION 1065.245 | 1065.245 Sample flow meter for batch sampling. | |
40:37.0.1.1.2.3.16.11 | SECTION 1065.247 | 1065.247 Diesel exhaust fluid flow rate. | |
40:37.0.1.1.2.3.16.12 | SECTION 1065.248 | 1065.248 Gas divider. | |
40:37.0.1.1.2.3.17 | SUBJGRP 17 | CO and CO2 Measurements | |
40:37.0.1.1.2.3.17.13 | SECTION 1065.250 | 1065.250 Nondispersive infrared analyzer. | |
40:37.0.1.1.2.3.18 | SUBJGRP 18 | Hydrocarbon Measurements | |
40:37.0.1.1.2.3.18.14 | SECTION 1065.260 | 1065.260 Flame-ionization detector. | |
40:37.0.1.1.2.3.18.15 | SECTION 1065.265 | 1065.265 Nonmethane cutter. | |
40:37.0.1.1.2.3.18.16 | SECTION 1065.266 | 1065.266 Fourier transform infrared analyzer. | |
40:37.0.1.1.2.3.18.17 | SECTION 1065.267 | 1065.267 Gas chromatograph with a flame ionization detector. | |
40:37.0.1.1.2.3.18.18 | SECTION 1065.269 | 1065.269 Photoacoustic analyzer for ethanol and methanol. | |
40:37.0.1.1.2.3.19 | SUBJGRP 19 | NOX and N2O Measurements | |
40:37.0.1.1.2.3.19.19 | SECTION 1065.270 | 1065.270 Chemiluminescent detector. | |
40:37.0.1.1.2.3.19.20 | SECTION 1065.272 | 1065.272 Nondispersive ultraviolet analyzer. | |
40:37.0.1.1.2.3.19.21 | SECTION 1065.275 | 1065.275 N2O measurement devices. | |
40:37.0.1.1.2.3.20 | SUBJGRP 20 | O2 Measurements | |
40:37.0.1.1.2.3.20.22 | SECTION 1065.280 | 1065.280 Paramagnetic and magnetopneumatic O2 detection analyzers. | |
40:37.0.1.1.2.3.21 | SUBJGRP 21 | Air-to-Fuel Ratio Measurements | |
40:37.0.1.1.2.3.21.23 | SECTION 1065.284 | 1065.284 Zirconia (ZrO2) analyzer. | |
40:37.0.1.1.2.3.22 | SUBJGRP 22 | PM Measurements | |
40:37.0.1.1.2.3.22.24 | SECTION 1065.290 | 1065.290 PM gravimetric balance. | |
40:37.0.1.1.2.3.22.25 | SECTION 1065.295 | 1065.295 PM inertial balance for field-testing analysis. |