Title 10
SECTION 50.60
50.60 Acceptance criteria for fracture prevention measures for lightwater nuclear power reactors for normal operation.
§ 50.60 Acceptance criteria for fracture prevention measures for lightwater nuclear power reactors for normal operation.(a) Except as provided in paragraph (b) of this section, all light-water nuclear power reactors, other than reactor facilities for which the certifications required under § 50.82(a)(1) have been submitted, must meet the fracture toughness and material surveillance program requirements for the reactor coolant pressure boundary set forth in appendices G and H to this part.
(b) Proposed alternatives to the described requirements in Appendices G and H of this part or portions thereof may be used when an exemption is granted by the Commission under § 50.12.
[48 FR 24009, May 27, 1983, as amended at 50 FR 50777, Dec. 12, 1985; 61 FR 39300, July 29, 1996]