Title 49 Part 179 → Subpart F → §179.500-4

Title 49 → Subtitle B → Chapter I → Subchapter C → Part 179 → Subpart F → §179.500-4

Electronic Code of Federal Regulations e-CFR

Title 49 Part 179 → Subpart F → §179.500-4

e-CFR data is current as of November 8, 2019

Title 49Subtitle BChapter ISubchapter CPart 179Subpart F → §179.500-4


Title 49: Transportation
PART 179—SPECIFICATIONS FOR TANK CARS
Subpart F—Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A)


§179.500-4   Thickness of wall.

(a) Minimum thickness of wall of each finished tank shall be such that at a pressure equal to 710 of the marked test pressure of the tank, the calculated fiber stress in psi at inner wall of tank multiplied by 3.0 will not exceed the tensile strength of any specimen taken from the tank and tested as prescribed in §179.500-7(b). Minimum wall thickness shall be 14 inch.

(b) Calculations to determine the maximum marked test pressure permitted to be marked on the tank shall be made by the formula:

P = [10S(D2d2)] / [7(D2 + d2)]

Where:

P = Maximum marked test pressure permitted;

S = U / 3.0

Where:

U = Tensile strength of that specimen which shows the lower tensile strength of the two specimens taken from the tank and tested as prescribed in §179.500-7(b).

3 = Factor of safety.

(D2d2/(D2 + d2) = The smaller value obtained for this factor by the operations specified in §179.500-4(c).

(c) Measure at one end, in a plane perpendicular to the longitudinal axis of the tank and at least 18 inches from that end before necking-down:

d = Maximum inside diameter (inches) for the location under consideration; to be determined by direct measurement to an accuracy of 0.05 inch.

t = Minimum thickness of wall for the location under consideration; to be determined by direct measurement to an accuracy of 0.001 inch.

Take D = d + 2t.

Calculate the value of (D2−d2)/(D2 + d2)

(1) Make similar measurements and calculation for a corresponding location at the other end of the tank.

(2) Use the smaller result obtained, from the foregoing, in making calculations prescribed in paragraph (b) of this section.

[29 FR 18995, Dec. 29, 1964. Redesignated at 32 FR 5606, Apr. 5, 1967, and amended by Amdt. 179-31, 47 FR 43067, Sept. 30, 1982; 66 FR 45391, Aug. 28, 2001]


© e-CFR 2019