Title 40
SECTION 86.508-78
86.508-78 Dynamometer.
§ 86.508-78 Dynamometer.(a) The dynamometer shall have a single roll with a diameter of at least 0.400 metre.
(b) The dynamometer shall be equipped with a roll revolution counter for measuring actual distance traveled.
(c) Flywheels or other means shall be used to stimulate the inertia specified in § 86.529.
(d) A variable speed cooling blower shall direct air to the vehicle. The blower outlet shall be at least 0.40 m 2 (4.31 ft 2) and shall be squarely positioned between 0.3 m (0.98 ft) and 0.45 m (1.48 ft) in front of the vehicle's front wheel. The velocity of the air at the blower outlet shall be within the following limits (as a function of roll speed):
Actual roll speed | Allowable cooling air speed |
---|---|
0 km/h to 5 km/h | 0 km/h to 10 km/h. |
5 km/h to 10 km/h | 0 km/h to roll speed + 5 km/h. |
10 km/h to 50 km/h | Roll speed ±5 km/h. |
50 km/h to 70 km/h | Roll speed ±10 pct. |
Above 70 km/h | At least 63 km/h. |
(e) The dynamometer shall comply with the tolerances in § 86.529.
[42 FR 1137, Jan. 5, 1977, as amended at 42 FR 56738, Oct. 28, 1977]