You may calculate percent reduction using any of the methods in paragraphs (a) through (d) of this section.

(a) Compliant line option. If all of your wet-out areas have PTE that meet the requirements of EPA Method 204 of appendix M of 40 CFR part 51, and all of your wet-out area organic HAP emissions and oven organic HAP emissions are vented to an add-on control device, use Equation 1 of this section to demonstrate compliance. In all other situations, use Equation 2 of this section to demonstrate compliance.

Where: PR = percent reduction; Inlet + HAP emissions entering the control device, lbs per year; Outlet = HAP emissions existing the control device to the atmosphere, lbs per year. Where: PR = percent reduction; WAEici = wet-out area organic HAP emissions, lbs per year, vented to a control device; WAEiu = wet-out area organic HAP emissions, lbs per year, not vented to a control device; Oju = oven organic HAP emissions, lbs per year, not vented to a control device; Ojci = oven organic HAP emissions, lbs per year, vented to a control device; WAEico = wet-out area organic HAP emissions, lbs per year, from the control device outlet; Ojco = oven organic HAP emissions, lbs per year, from the control device outlet.

(b) Averaging option. Use Equation 3 of this section to calculate percent reduction.

Where: PR = percent reduction; WAEici = wet-out area organic HAP emissions from wet-out area i, lbs per year, sent to a control device; WAEiu = wet-out area organic HAP emissions from wet-out area i, lbs per year, not sent to a control device; WAEico = wet-out area organic HAP emissions from wet-out area i, lbs per year, at the outlet of a control device; Oju = organic HAP emissions from oven j, lbs per year, not sent to a control device; Ojci = organic HAP emissions from oven j, lbs per year, sent to a control device; Ojco = organic HAP emissions from oven j, lbs per year, at the outlet of the control device; m = number of wet-out areas; n = number of ovens.

(c) Add-on control device option. Use Equation 1 of this section to calculate percent reduction.

(d) Combination option. Use Equations 1 through 3 of this section, as applicable, to calculate percent reduction.