Aerosols - Unacceptable Substitutes

End-use Substitute Decision Further information
Propellants HFC-125 Unacceptable as of January 1, 2016 HFC-125 has a Chemical Abstracts Service Registry Number (CAS Reg. No.) of 354-33-6 and it is also known by the name 1,1,1,2,2-pentafluoropropane. HFC-125 has a GWP of 3,500. Other substitutes will be available for this end-use with lower overall risk to human health and the environment by the status change date.
Products using this propellant that are manufactured prior to January 1, 2016 may be sold, imported, exported, distributed and used after that date.
Propellants HFC-134a Unacceptable as of July 20, 2016, except uses listed as acceptable, subject to use conditions HFC-134a has a Chemical Abstracts Service Registry Number (CAS Reg. No.) of 811-97-2 and it is also known by the name 1,1,1,2-tetrafluoropropane. HFC-134a has a GWP of 1,430. Other substitutes will be available for this end-use with lower overall risk to human health and the environment by the status change date.
Products using this propellant that are manufactured prior to July 20, 2016 may be sold, imported, exported, distributed and used after that date.
Propellants HFC-227ea and blends of HFC-134a and HFC-227ea Unacceptable as of July 20, 2016, except uses listed as acceptable, subject to use conditions HFC-227ea has a Chemical Abstracts Service Registry Number (CAS Reg. No.) of 431-89-0 and it is also known by the name 1,1,1,2,3,3,3-heptafluoropropane. HFC-134a has a Chemical Abstracts Service Registry Number (CAS Reg. No.) of 811-97-2 and it is also known by the name 1,1,1,2-tetrafluoropropane.
HFC-227ea and HFC-134a have GWPs of 3,220 and 1,430, respectively. Other substitutes will be available for this end-use with lower overall risk to human health and the environment by the status change date.
Products using these propellants that are manufactured prior to July 20, 2016 may be sold, imported, exported, distributed and used after that date.
Propellants HCFC-22 and HCFC-142b Unacceptable effective September 18, 2015 Use or introduction into interstate commerce of virgin HCFC-22 and HCFC-142b for aerosols is prohibited as of January 1, 2010 under EPA's regulations at 40 CFR part 82 subpart A. These propellants have ozone depletion potentials of 0.055 and 0.065, respectively.