Table 3 to Subpart D of Part 65—TRE Parameters for HON Referencing Subparts
a
| Existing or new? | Halogenated vent stream? | Values of terms for TRE equation: TRE = A * [ B + C + D + E + F ] |
|---|
| A | B | C | D | E | F | Equation number |
|---|
| Existing | Yes | 1/EHAP | 3.995 | 0.05200Q | 0 | −0.001769H | 0.0009700ETOC | 33 |
| | No | 1/EHAP | 1.935 | 0.3660Q | 0 | −0.007687H | −0.000733ETOC | 34 |
| | | 1/EHAP | 1.492 | 0.06267Q | 0 | 0.03177H | −0.001159ETOC | 35 |
| | | 1/EHAP | 2.519 | 0.01183Q | 0 | 0.01300H | 0.04790ETOC | 36 |
| New | Yes | 1/EHAP | 1.0895 | 0.01417Q | 0 | −0.000482H | 0.0002645ETOC | 37 |
| | No | 1/EHAP | 0.5276 | 0.0998Q | 0 | −0.002096H | −0.0002000ETOC | 38 |
| | | 1/EHAP | 0.4068 | 0.0171Q | 0 | 0.008664H | −0.000316ETOC | 39 |
| | | 1/EHAP | 0.6868 | 0.00321Q | 0 | 0.003546H | 0.01306ETOC | 40
|
| a Use according to procedures outlined in § 65.64(h). |