eCFR.io
Daily eCFR

Table 8 to Subpart XXXX of Part 63—Initial Compliance With the Emission Limits for Puncture Sealant Application Affected Sources

Initial Compliance With the Emission Limits for Puncture Sealant Application Affected Sources

CorpusDaily eCFR
Displayed edition2026-04-27
Last updated2026-04-27

Table 8 to Subpart XXXX of Part 63—Initial Compliance With the Emission Limits for Puncture Sealant Application Affected Sources

As stated in § 63.6002, you must show initial compliance with the emission limits for puncture sealant application affected sources according to the following table:

For . . .For the following emission limit . . .You have demonstrated initial compliance if . . .
1. Sources complying with the overall control efficiency alternative in § 63.5989(a)The percent reduction option in Table 3 to this subpart, option 1You demonstrate that you conducted the performance tests, determined the overall efficiency of your control system, demonstrated that the applicable limits in Table 3 to this subpart, option 1, have been achieved, and established the operating limits in Table 4 of this subpart for your equipment according to the applicable procedures in § 63.6000(b).
2. Sources complying with the permanent total enclosure and control device efficiency alternative in § 63.5989(b)The percent reduction option in Table 3 to this subpart, option 1You demonstrate that you conducted the performance tests, determined the individual efficiencies of your capture and control systems, demonstrated that the applicable limits in Table 3 to this subpart, option 1, have been achieved, and established the operating limits in Table 4 of this subpart for your equipment according to the applicable procedures in § 63.6000(b).
3. Sources complying with the monthly average alternative in § 63.5989(c) without using an add-on control deviceThe HAP constituent option in Table 3 to this subpart, option 2You demonstrate that the monthly average HAP emissions for each monthly operating period do not exceed the HAP constituent emission limits in Table 3 to this subpart, option 2, determined according to the applicable procedures in § 63.6000(c) and (d)(1).
4. Sources complying with the HAP constituent alternative in § 63.5989(d) by using an add-on control deviceThe HAP constituent option in Table 3 to this subpart, option 2You demonstrate that the monthly average HAP emissions for each monthly operating period do not exceed the HAP constituent emission limits in Table 3 to this subpart, option 2, determined according to the applicable procedures in § 63.6000(c), (d)(2) and (3), and (e) through (f).