Table 2 to Subpart VVVV—Emission Limitations for New Large Municipal Waste Combustors
| For the air pollutant | If your affected facility is a new large municipal waste combustor, you must meet this
emission limit, corrected to 7 percent oxygen a |
|---|---|
| Particulate matter | 5.1 mg/dscm. |
| Opacity | 10 percent opacity (6-minute block average). |
| Cadmium | 2.3 ug/dscm. |
| Lead | 23 ug/dscm. |
| Mercury | 32 ug/dscm or 85 percent reduction by weight. |
| Sulfur dioxide | 14 parts per million by volume dry basis or 79 percent reduction by weight or volume (daily 24-hour geometric average). |
| Hydrogen chloride | 7.2 parts per million by volume dry basis or 98 percent reduction by weight or volume. |
| Dioxins/furans | 11 nanograms per dry standard cubic meter (total mass). |
| Nitrogen oxides | 50 parts per million by volume dry basis (daily 24-hour arithmetic average). |
| a Measured at the combustor outlet in conjunction with a measurement of oxygen concentration. CEMS data during warmup, startup, and shutdown, as defined in this subpart, are not corrected to 7 percent oxygen, and are used as measured. The averaging times are specified in greater detail in § 60.5940. |