eCFR.io
Daily eCFR

Table 1 to Subpart RRR<span class="standard">a</span> of Part 60—Emission Limits and Standards for Vent Streams

Emission Limits and Standards for Vent Streams

CorpusDaily eCFR
Displayed edition2026-04-23
Last updated2026-04-23

Table 1 to Subpart RRRa of Part 60—Emission Limits and Standards for Vent Streams

For each. . .You must. . .
1. Vent streama. Reduce emissions of TOC (minus methane and ethane) by 98 weight-percent, or to a TOC (minus methane and ethane) concentration of 20 ppmv on a dry basis corrected to 3 percent oxygen by venting emissions through a closed vent system to any combination of non-flare control devices and/or recovery system and meet the requirements specified in § 60.703a and § 60.710a; or

b. Reduce emissions of TOC (minus methane and ethane) by venting emissions through a closed vent system to a flare and meet the requirements specified in § 60.709a and § 60.710a.