Title 40

PART 60 SUBPART KKKK

Subpart KKKK - Standards of Performance for Stationary Combustion Turbines Source:71 FR 38497, July 6, 2006, unless otherwise noted.

40:8.0.1.1.1.37.279SUBJGRP 279
Introduction
40:8.0.1.1.1.37.279.1SECTION 60.4300
   60.4300 What is the purpose of this subpart
40:8.0.1.1.1.37.280SUBJGRP 280
Applicability
40:8.0.1.1.1.37.280.2SECTION 60.4305
   60.4305 Does this subpart apply to my stationary combustion turbine
40:8.0.1.1.1.37.280.3SECTION 60.4310
   60.4310 What types of operations are exempt from these standards of performance
40:8.0.1.1.1.37.281SUBJGRP 281
Emission Limits
40:8.0.1.1.1.37.281.4SECTION 60.4315
   60.4315 What pollutants are regulated by this subpart
40:8.0.1.1.1.37.281.5SECTION 60.4320
   60.4320 What emission limits must I meet for nitrogen oxides (NOX)
40:8.0.1.1.1.37.281.6SECTION 60.4325
   60.4325 What emission limits must I meet for NOX if my turbine burns both natural gas and distillate oil (or some other combination of fuels)
40:8.0.1.1.1.37.281.7SECTION 60.4330
   60.4330 What emission limits must I meet for sulfur dioxide (SO2
40:8.0.1.1.1.37.282SUBJGRP 282
General Compliance Requirements
40:8.0.1.1.1.37.282.8SECTION 60.4333
   60.4333 What are my general requirements for complying with this subpart
40:8.0.1.1.1.37.283SUBJGRP 283
Monitoring
40:8.0.1.1.1.37.283.9SECTION 60.4335
   60.4335 How do I demonstrate compliance for NOX if I use water or steam injection
40:8.0.1.1.1.37.283.10SECTION 60.4340
   60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection
40:8.0.1.1.1.37.283.11SECTION 60.4345
   60.4345 What are the requirements for the continuous emission monitoring system equipment, if I choose to use this option
40:8.0.1.1.1.37.283.12SECTION 60.4350
   60.4350 How do I use data from the continuous emission monitoring equipment to identify excess emissions
40:8.0.1.1.1.37.283.13SECTION 60.4355
   60.4355 How do I establish and document a proper parameter monitoring plan
40:8.0.1.1.1.37.283.14SECTION 60.4360
   60.4360 How do I determine the total sulfur content of the turbine's combustion fuel
40:8.0.1.1.1.37.283.15SECTION 60.4365
   60.4365 How can I be exempted from monitoring the total sulfur content of the fuel
40:8.0.1.1.1.37.283.16SECTION 60.4370
   60.4370 How often must I determine the sulfur content of the fuel
40:8.0.1.1.1.37.284SUBJGRP 284
Reporting
40:8.0.1.1.1.37.284.17SECTION 60.4375
   60.4375 What reports must I submit
40:8.0.1.1.1.37.284.18SECTION 60.4380
   60.4380 How are excess emissions and monitor downtime defined for NOX
40:8.0.1.1.1.37.284.19SECTION 60.4385
   60.4385 How are excess emissions and monitoring downtime defined for SO2
40:8.0.1.1.1.37.284.20SECTION 60.4390
   60.4390 What are my reporting requirements if I operate an emergency combustion turbine or a research and development turbine
40:8.0.1.1.1.37.284.21SECTION 60.4395
   60.4395 When must I submit my reports
40:8.0.1.1.1.37.285SUBJGRP 285
Performance Tests
40:8.0.1.1.1.37.285.22SECTION 60.4400
   60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX
40:8.0.1.1.1.37.285.23SECTION 60.4405
   60.4405 How do I perform the initial performance test if I have chosen to install a NOX-diluent CEMS
40:8.0.1.1.1.37.285.24SECTION 60.4410
   60.4410 How do I establish a valid parameter range if I have chosen to continuously monitor parameters
40:8.0.1.1.1.37.285.25SECTION 60.4415
   60.4415 How do I conduct the initial and subsequent performance tests for sulfur
40:8.0.1.1.1.37.286SUBJGRP 286
Definitions
40:8.0.1.1.1.37.286.26SECTION 60.4420
   60.4420 What definitions apply to this subpart
40:8.0.1.1.1.37.287.27.55APPENDIX
   Table 1 to Subpart KKKK of Part 60 - Nitrogen Oxide Emission Limits for New Stationary Combustion Turbines