Operating parameters to be monitoredMinimum frequencyControl system
Data measurementData recordingDry scrubber followed by fabric filterWet scrubberDry scrubber followed by fabric filter and wet scrubber
Maximum operating parameters:
Maximum charge rateContinuous1 × hour✔✔✔
Maximum fabric filter inlet temperatureContinuous1 × minute✔✔
Maximum flue gas temperatureContinuous1 × minute✔✔
Minimum operating parameters:
Minimum secondary chamber temperatureContinuous1 × minute✔✔✔
Minimum dioxin/furan sorbent flow rateHourly1 × hour✔✔
Minimum HCI sorbent flow rateHourly1 × hour✔✔
Minimum mercury (Hg) sorbent flow rateHourly1 × hour✔✔
Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubberContinuous1 × minute✔✔
Minimum scrubber liquor flow rateContinuous1 × minute✔✔
Minimum scrubber liquor pHContinuous1 × minute✔✔