Table 2 to Subpart CCCC of Part 60—Operating Limits for Wet Scrubbers
| For these operating parameters | You must establish these operating limits | And monitoring using these minimum frequencies |
|---|
| Data measurement | Data recording | Averaging time |
|---|
| Charge rate | Maximum charge rate | Continuous | Every hour | Daily (batch units) 3-hour rolling (continuous and intermittent units).1 |
| Pressure drop across the wet scrubber or amperage to wet scrubber | Minimum pressure drop or amperage | Continuous | Every 15 minutes | 3-hour rolling.1 |
| Scrubber liquor flow rate | Minimum flow rate | Continuous | Every 15 minutes | 3-hour rolling.1 |
| Scrubber liquor pH | Minimum pH | Continuous | Every 15 minutes | 3-hour rolling.1 |
| 1 Calculated each hour as the average of the previous 3 operating hours. |