Table 6 to Subpart BBBB of Part 60—Model Rule—Requirements for Validating Continuous Emission Monitoring Systems (CEMS)
For the following continuous emission monitoring systems
Use the following methods in appendix A of this part to validate poollutant concentratin levels
Use the following methods in appendix A of this part to measure oxygen (or carbon dioxide)
1. Nitrogen Oxides (Class I units only) a
Method 7, 7A, 7B,7C, 7D, or 7E
Method 3 or 3A.
2. Sulfur Dioxide
Method 6 or 6C
Method 3 or 3A.
3. Carbon Monoxide
Method 10, 10A, or 10B
Method 3 or 3A.
a Class I units mean small municipal waste combustion units subject to this subpart that are located at municipal waste combustion plants with an aggregate plant combustion capacity greater than 250 tons per day of municipal solid waste. See § 60.1940 for definitions.