Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate

40:5.0.1.1.1.19.1.6.3 : Appendix E

Appendix E to Part 52 - Performance Specifications and, Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate

1. Principle and applicability.

1.1 Principle. Effluent stream gas volumetric flow rates are sampled and analyzed by a continuous measurement system. To verify the measurement system performance, values obtained from the measurement system are compared against simultaneous values obtained using the reference method. These comparison tests will be performed to determine the relative accuracy, and drift of the measurement system over the range of operating conditions expected to occur during normal operation of the source. If the measurement system is such that the specified tests in section 5.1 for drift do not apply, those test procedures shall be disregarded.

1.2 Applicability. This method is applicable to subparts which require continuous gas volumetric flow rate measurement. Specifications are given in terms of performance. Test procedures are given for determining compliance with performance specifications.

2. Apparatus.

2.1 Continuous measurement system for determining stack gas volumetric flow rate.

2.2 Equipment for measurement of stack gas volumetric flow rate as specified in the reference method.

3. Definitions.

3.1 Measurement system. The total equipment required for the determination of the gas volumetric flow rate in a duct or stack. The system consists of three major subsystems:

3.1.1 Sampling interface. That portion of the measurement system that performs one or more of the following operations: Delineation, acquisition, transportation, and conditioning of a signal from the stack gas and protection of the analyzer from any hostile aspects of the source environment.

3.1.2 Analyzer. That portion of the measurement system which senses the stack gas flow rate or velocity pressure and generates a signal output that is a function of the flow rate or velocity of the gases.

3.1.3 Data presentation. That portion of the measurement system that provides a display of the output signal in terms of volumetric flow rate units, or other units which are convertible to volumetric flow rate units.

3.2 Span. The value of gas volumetric flow rate at which the measurement system is set to produce the maximum data display output. For the purposes of this method, the span shall be set at 1.5 times the maximum volumetric flow rate expected under varying operating conditions of the source.

3.3 Zero drift. The change in measurement system output over a stated period of time of normal continuous operation when gas volumetric flow rate at the time of the measurements is zero.

3.4 Calibration drift. The change in measurement system output over a stated time period of normal continuous operation when the gas volumetric flow rate at the time of the measurement is 67 percent of the span value.

3.5 Operation period. A minimum period of time over which a measurement system is expected to operate within certain performance specifications without unscheduled maintenance, repair, or adjustment.

3.6 Orientation sensitivity. The angular tolerance to which the sensor can be misaligned from its correct orientation to measure the flow rate vector before a specified error occurs in the indicated flow rate compared to the reference flow rate.

3.7 Reference method. Method 2 as delineated in 40 CFR Part 60.

4. Measurement system performance specifications. A measurement system must meet the performance specifications in Table E-1 to be considered acceptable under this method.

Table E-1

Parameter Specifications
Accuracy (relative) <10 percent of mean reference value (paragraph 6.3.1).
Zero drift (24 hours) <3 percent of span (paragraph 6.3.2).
Calibration drift (24 hours) <3 percent of span (paragraph 6.3.3).
Operational period <168 hours minimum.