Title 40
PART 1042 APPENDIX II
E3 mode No. | Engine speed 1 | Percent of maximum test power |
Weighting factors |
---|---|---|---|
1 | Maximum test speed | 100 | 0.2 |
2 | 91% | 75 | 0.5 |
3 | 80% | 50 | 0.15 |
4 | 63% | 25 | 0.15 |
1 Maximum test speed is defined in 40 CFR part 1065. Percent speed values are relative to maximum test speed.
(2) The following duty cycle applies for ramped-modal testing:
RMC mode |
Time in mode (seconds) |
Engine speed 1 3 |
Power (percent) 2 3 |
---|---|---|---|
1a Steady-state | 229 | Maximum test speed | 100%. |
1b Transition | 20 | Linear transition | Linear transition in torque. |
2a Steady-state | 166 | 63% | 25%. |
2b Transition | 20 | Linear transition | Linear transition in torque. |
3a Steady-state | 570 | 91% | 75%. |
3b Transition | 20 | Linear transition | Linear transition in torque. |
4a Steady-state | 175 | 80% | 50%. |
1 Maximum test speed is defined in 40 CFR part 1065. Percent speed is relative to maximum test speed.
2 The percent power is relative to the maximum test power.
3 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting.
(b) The following duty cycles apply as specified in § 1042.505(b)(2):
(1) The following duty cycle applies for discrete-mode testing:
E5 mode No. | Engine speed 1 |
Percent of maximum test power |
Weighting factors |
---|---|---|---|
1 | Maximum test speed | 100 | 0.08 |
2 | 91% | 75 | 0.13 |
3 | 80% | 50 | 0.17 |
4 | 63% | 25 | 0.32 |
5 | Warm idle | 0 | 0.3 |
1 Maximum test speed is defined in 40 CFR part 1065. Percent speed values are relative to maximum test speed.
(2) The following duty cycle applies for ramped-modal testing:
RMC mode |
Time in mode (seconds) |
Engine speed 1 3 |
Power (percent) 2 3 |
---|---|---|---|
1a Steady-state | 167 | Warm idle | 0. |
1b Transition | 20 | Linear transition | Linear transition in torque. |
2a Steady-state | 85 | Maximum test speed | 100%. |
2b Transition | 20 | Linear transition | Linear transition in torque. |
3a Steady-state | 354 | 63% | 25%. |
3b Transition | 20 | Linear transition | Linear transition in torque. |
4a Steady-state | 141 | 91% | 75%. |
4b Transition | 20 | Linear transition | Linear transition in torque. |
5a Steady-state | 182 | 80% | 50%. |
5b Transition | 20 | Linear transition | Linear transition in torque. |
6 Steady-state | 171 | Warm idle | 0. |
1 Maximum test speed is defined in 40 CFR part 1065. Percent speed is relative to maximum test speed.
2 The percent power is relative to the maximum test power.
3 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting.
(c) The following duty cycles apply as specified in § 1042.505(b)(3):
(1) The following duty cycle applies for discrete-mode testing:
E2 mode No. | Engine speed 1 |
Torque (percent) 2 |
Weighting factors |
---|---|---|---|
1 | Engine Governed | 100 | 0.2 |
2 | Engine Governed | 75 | 0.5 |
3 | Engine Governed | 50 | 0.15 |
4 | Engine Governed | 25 | 0.15 |
1 Speed terms are defined in 40 CFR part 1065.
2 The percent torque is relative to the maximum test torque as defined in 40 CFR part 1065.
(2) The following duty cycle applies for ramped-modal testing:
RMC mode | Time in mode (seconds) |
Engine speed | Torque (percent) 1 2 |
---|---|---|---|
1a Steady-state | 229 | Engine Governed | 100%. |
1b Transition | 20 | Engine Governed | Linear transition. |
2a Steady-state | 166 | Engine Governed | 25%. |
2b Transition | 20 | Engine Governed | Linear transition. |
3a Steady-state | 570 | Engine Governed | 75%. |
3b Transition | 20 | Engine Governed | Linear transition. |
4a Steady-state | 175 | Engine Governed | 50%. |
1 The percent torque is relative to the maximum test torque as defined in 40 CFR part 1065.
2 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode.