Subpart E - Explosives Source:61 FR 36801, July 12, 1996, unless otherwise noted.

30:1.0.1.8.30.5.159SUBJGRP 159
Storage - Surface and Underground
30:1.0.1.8.30.5.159.1SECTION 57.6000
   57.6000 Definitions.
30:1.0.1.8.30.5.159.2SECTION 57.6100
   57.6100 Separation of stored explosive material.
30:1.0.1.8.30.5.159.3SECTION 57.6101
   57.6101 Areas around explosive material storage facilities.
30:1.0.1.8.30.5.159.4SECTION 57.6102
   57.6102 Explosive material storage practices.
30:1.0.1.8.30.5.160SUBJGRP 160
Storage - Surface Only
30:1.0.1.8.30.5.160.5SECTION 57.6130
   57.6130 Explosive material storage facilities.
30:1.0.1.8.30.5.160.6SECTION 57.6131
   57.6131 Location of explosive material storage facilities.
30:1.0.1.8.30.5.160.7SECTION 57.6132
   57.6132 Magazine requirements.
30:1.0.1.8.30.5.160.8SECTION 57.6133
   57.6133 Powder chests.
30:1.0.1.8.30.5.161SUBJGRP 161
Storage - Underground Only
30:1.0.1.8.30.5.161.9SECTION 57.6160
   57.6160 Main facilities.
30:1.0.1.8.30.5.161.10SECTION 57.6161
   57.6161 Auxiliary facilities.
30:1.0.1.8.30.5.162SUBJGRP 162
Transportation - Surface and Underground
30:1.0.1.8.30.5.162.11SECTION 57.6200
   57.6200 Delivery to storage or blast site areas.
30:1.0.1.8.30.5.162.12SECTION 57.6201
   57.6201 Separation of transported explosive material.
30:1.0.1.8.30.5.162.13SECTION 57.6202
   57.6202 Vehicles.
30:1.0.1.8.30.5.162.14SECTION 57.6203
   57.6203 Locomotives.
30:1.0.1.8.30.5.162.15SECTION 57.6204
   57.6204 Hoists.
30:1.0.1.8.30.5.162.16SECTION 57.6205
   57.6205 Conveying explosives by hand.
30:1.0.1.8.30.5.163SUBJGRP 163
USE - SURFACE AND UNDERGROUND
30:1.0.1.8.30.5.163.17SECTION 57.6300
   57.6300 Control of blasting operations.
30:1.0.1.8.30.5.163.18SECTION 57.6301
   57.6301 Blasthole obstruction check.
30:1.0.1.8.30.5.163.19SECTION 57.6302
   57.6302 Separation of explosive material.
30:1.0.1.8.30.5.163.20SECTION 57.6303
   57.6303 Initiation preparation.
30:1.0.1.8.30.5.163.21SECTION 57.6304
   57.6304 Primer protection.
30:1.0.1.8.30.5.163.22SECTION 57.6305
   57.6305 Unused explosive material.
30:1.0.1.8.30.5.163.23SECTION 57.6306
   57.6306 Loading, blasting, and security.
30:1.0.1.8.30.5.163.24SECTION 57.6307
   57.6307 Drill stem loading.
30:1.0.1.8.30.5.163.25SECTION 57.6308
   57.6308 Initiation systems.
30:1.0.1.8.30.5.163.26SECTION 57.6309
   57.6309 Fuel oil requirements for ANFO.
30:1.0.1.8.30.5.163.27SECTION 57.6310
   57.6310 Misfire waiting period.
30:1.0.1.8.30.5.163.28SECTION 57.6311
   57.6311 Handling of misfires.
30:1.0.1.8.30.5.163.29SECTION 57.6312
   57.6312 Secondary blasting.
30:1.0.1.8.30.5.164SUBJGRP 164
Electric Blasting - Surface and Underground
30:1.0.1.8.30.5.164.30SECTION 57.6400
   57.6400 Compatibility of electric detonators.
30:1.0.1.8.30.5.164.31SECTION 57.6401
   57.6401 Shunting.
30:1.0.1.8.30.5.164.32SECTION 57.6402
   57.6402 Deenergized circuits near detonators.
30:1.0.1.8.30.5.164.33SECTION 57.6403
   57.6403 Branch circuits.
30:1.0.1.8.30.5.164.34SECTION 57.6404
   57.6404 Separation of blasting circuits from power source.
30:1.0.1.8.30.5.164.35SECTION 57.6405
   57.6405 Firing devices.
30:1.0.1.8.30.5.164.36SECTION 57.6406
   57.6406 Duration of current flow.
30:1.0.1.8.30.5.164.37SECTION 57.6407
   57.6407 Circuit testing.
30:1.0.1.8.30.5.165SUBJGRP 165
Nonelectric Blasting - Surface and Underground
30:1.0.1.8.30.5.165.38SECTION 57.6500
   57.6500 Damaged initiating material.
30:1.0.1.8.30.5.165.39SECTION 57.6501
   57.6501 Nonelectric initiation systems.
30:1.0.1.8.30.5.165.40SECTION 57.6502
   57.6502 Safety fuse.
30:1.0.1.8.30.5.166SUBJGRP 166
Extraneous Electricity - Surface and Underground
30:1.0.1.8.30.5.166.41SECTION 57.6600
   57.6600 Loading practices.
30:1.0.1.8.30.5.166.42SECTION 57.6601
   57.6601 Grounding.
30:1.0.1.8.30.5.166.43SECTION 57.6602
   57.6602 Static electricity dissipation during loading.
30:1.0.1.8.30.5.166.44SECTION 57.6603
   57.6603 Air gap.
30:1.0.1.8.30.5.166.45SECTION 57.6604
   57.6604 Precautions during storms.
30:1.0.1.8.30.5.166.46SECTION 57.6605
   57.6605 Isolation of blasting circuits.
30:1.0.1.8.30.5.167SUBJGRP 167
Equipment/Tools - Surface and Underground
30:1.0.1.8.30.5.167.47SECTION 57.6700
   57.6700 Nonsparking tools.
30:1.0.1.8.30.5.167.48SECTION 57.6701
   57.6701 Tamping and loading pole requirements.
30:1.0.1.8.30.5.168SUBJGRP 168
Maintenance - Surface and Underground
30:1.0.1.8.30.5.168.49SECTION 57.6800
   57.6800 Storage facilities.
30:1.0.1.8.30.5.168.50SECTION 57.6801
   57.6801 Vehicle repair.
30:1.0.1.8.30.5.168.51SECTION 57.6802
   57.6802 Bulk delivery vehicles.
30:1.0.1.8.30.5.168.52SECTION 57.6803
   57.6803 Blasting lines.
30:1.0.1.8.30.5.169SUBJGRP 169
General Requirements - Surface and Underground
30:1.0.1.8.30.5.169.53SECTION 57.6900
   57.6900 Damaged or deteriorated explosive material.
30:1.0.1.8.30.5.169.54SECTION 57.6901
   57.6901 Black powder.
30:1.0.1.8.30.5.169.55SECTION 57.6902
   57.6902 Excessive temperatures.
30:1.0.1.8.30.5.169.56SECTION 57.6903
   57.6903 Burning explosive material.
30:1.0.1.8.30.5.169.57SECTION 57.6904
   57.6904 Smoking and open flames.
30:1.0.1.8.30.5.169.58SECTION 57.6905
   57.6905 Protection of explosive material.
30:1.0.1.8.30.5.170SUBJGRP 170
General Requirements - Underground Only
30:1.0.1.8.30.5.170.59SECTION 57.6960
   57.6960 Mixing of explosive material.