Title 29

SECTION 1918.94

1918.94 Ventilation and atmospheric conditions (See also § 1918.2, definitions of Hazardous cargo, materials, substance or atmosphere and Ro-Ro operations).

§ 1918.94 Ventilation and atmospheric conditions (See also § 1918.2, definitions of Hazardous cargo, materials, substance or atmosphere and Ro-Ro operations).

(a) Ventilation with respect to carbon monoxide. (1) When internal combustion engines exhaust into a hold, intermediate deck, or any other compartment, the employer shall ensure that the atmosphere is tested as frequently as needed to prevent carbon monoxide (CO) concentrations from exceeding allowable limits. Such tests shall be made in the area in which employees are working by persons competent in the use of the test equipment and procedures. If operations are in a deep tank or refrigerated compartment, the first test shall be made within one half hour of the time the engine starts. To decide the need for further testing, the initial test in all other cargo handling areas shall be taken no later than one hour after the time the engine starts.

(i) The CO content of the atmosphere in a compartment, hold, or any enclosed space shall be maintained at not more than 50 parts per million (ppm) (0.005%) as an eight hour average area level and employees shall be removed from the enclosed space if the CO concentration exceeds a ceiling of 100 ppm (0.01%). Exception: The ceiling shall be 200 ppm (0.02%) instead of 100 ppm (0.01%) for Ro-Ro operations.

12 [Reserved]

Note to paragraph (a)(1)(i):

The term eight hour average area level means that for any period in which the concentration exceeds 50 parts per million, the concentration shall be maintained for a corresponding period below 50 parts per million.

(ii) When both natural ventilation and the vessel's ventilation system are inadequate to keep the CO concentration within the allowable limits, the employer shall use supplementary means to bring such concentration within allowable limits, as determined by monitoring.

(2) The intakes of portable blowers and any exposed belt drives shall be guarded to prevent injury to employees.

(3) The frames of portable blowers shall be grounded at the source of the current by means of an equipment grounding conductor run with or enclosing the circuit conductors. When the vessel is the source of the current, the equipment grounding conductor shall be bonded to the structure of the vessel. Electric cords shall be free from visible defects.

(b) Fumigated grains. (1) Before commencing to handle bulk grain in any compartment of a vessel in which employees will or may be present, the employer shall:

(i) Determine whether the grain has been or will be fumigated at the elevator; and

(ii) Determine whether that compartment, or any cargo within it loaded at a prior berth, has been treated with a fumigant or any other chemical.

(2) If fumigant or chemical treatment has been carried out, or if there is reason to suspect that such treatment has been carried out, it shall be determined by atmospheric testing that the compartment's atmosphere is within allowable limits. (See paragraph (b)(3) of this section.)

(3) A test of the fumigant concentration in the atmosphere of the compartment shall be made after loading begins and before employees enter the compartment. Additional tests shall be made as often as necessary to ensure that hazardous concentrations do not develop.

(i) Tests for fumigant concentration shall be conducted by a designated person, who shall be thoroughly familiar with the characteristics of the fumigant being used, the correct procedure for measurement, the proper measuring equipment to be used, the fumigant manufacturers' recommendations and warnings, and the proper use of personal protective equipment to guard against the specific hazard.

(ii) If the concentration in any compartment reaches the level specified as hazardous by the fumigant manufacturer, or exceeds the permissible exposure limits of part 1910, subpart Z of this chapter, whichever is lower, all employees shall be removed from such compartments and shall not be permitted to reenter until tests prove that the atmosphere is within allowable limits.

(iii) No employee shall be permitted to enter any compartment in which grain fumigation has been carried out, or any compartment immediately next to such a compartment, until it has been determined by testing that the atmosphere in the compartment to be entered is within allowable limits for entry.

(iv) In the event a compartment containing a hazardous or unknown concentration of fumigants must be entered for testing of the atmosphere, or for emergency purposes, each employee entering shall be protected by respiratory protective equipment following the provisions of § 1918.102, and by any protective clothing and other personal protective equipment recommended by the fumigant manufacturer for protection against the particular hazard. At least two other employees shall be stationed outside the compartment as observers, to provide rescue services in case of emergency. The observers shall be equipped with similar personal protective equipment.

(v) One or more employees on duty shall be equipped and trained to provide any specific emergency medical treatment stipulated for the particular fumigant.

(vi) Emergency equipment required by this paragraph shall be readily accessible wherever fumigated grains are being handled.

(4) If a compartment is treated for local infestation before loading grain by a chemical other than a fumigant, the employee applying the treatment, and any other employees entering the compartment, shall be provided with and required to use any personal protective equipment recommended by the manufacturer of the product to protect them against the effects of exposure.

(c) Fumigated tobacco. The employer shall not load break-bulk tobacco until the carrier has provided written notification about whether or not the cargo has been fumigated. If break-bulk tobacco cargo has been treated with any toxic fumigant, loading shall not commence until a written warranty has been received from the fumigation facility that the aeration of the cargo has been such as to reduce the concentration of the fumigant to within the level specified as hazardous by the fumigant manufacturer, or does not exceed the permissible exposure limits of part 1910, subpart Z of this chapter, whichever is lower. Such notification and warranty shall be maintained for at least 30 days after the loading of the tobacco has been completed, and shall be available for inspection.

(d) Other fumigated cargoes. Before commencing to load or discharge fumigated cargo other than the cargo specifically addressed in paragraphs (b) and (c) of this section, the employer shall determine that the concentration of fumigants is within the level specified as hazardous by the fumigant manufacturer, or does not exceed the permissible exposure limits of part 1910, subpart Z of this chapter, whichever is lower.

(e) Grain dust. When employees are exposed to concentrations of grain dust greater than the allowable limit found in subpart Z of part 1910 of this chapter, they shall be protected by suitable respiratory protective equipment as required by § 1918.102.

(f) Catch of menhaden and similar species of fish. (1) The provisions of this paragraph shall not apply to vessels having and utilizing refrigerated holds for the carriage of all cargo.

(2) After a vessel has arrived at berth for discharge of menhaden, but before personnel enter the hold, and as frequently thereafter as tests show to be necessary, tests shall be made of the atmosphere in the vessel's hold to ensure a safe work space. The tests shall be done for the presence of hydrogen sulfide and for oxygen deficiency.

(3) Tests required by paragraph (f)(2) of this section shall be made by designated supervisory personnel, trained and competent in the nature of hazards and the use of test equipment and procedures.

(4) Before employees enter a hold it shall be tested for hydrogen sulfide and oxygen deficiency. Employees shall not enter the hold when the hydrogen sulfide level exceeds 20 ppm ceiling or when the oxygen content is less than 19.5 percent, except in emergencies.

[62 FR 40202, July 25, 1997, as amended at 65 FR 40946, June 30, 2000]