Title 24

PART 3285

Part 3285 - Model Manufactured Home Installation Standards

PART 3285 - MODEL MANUFACTURED HOME INSTALLATION STANDARDS Authority:42 U.S.C. 3535(d), 5403, 5404, and 5424. Source:72 FR 59362, Oct. 19, 2007, unless otherwise noted.

24:5.1.4.1.5.1SUBPART A
Subpart A - General
24:5.1.4.1.5.1.1.1SECTION 3285.1
   3285.1 Administration.
24:5.1.4.1.5.1.1.2SECTION 3285.2
   3285.2 Manufacturer installation instructions.
24:5.1.4.1.5.1.1.3SECTION 3285.3
   3285.3 Alterations during initial installation.
24:5.1.4.1.5.1.1.4SECTION 3285.4
   3285.4 Incorporation by reference (IBR).
24:5.1.4.1.5.1.1.5SECTION 3285.5
   3285.5 Definitions.
24:5.1.4.1.5.1.1.6SECTION 3285.6
   3285.6 Final leveling of manufactured home.
24:5.1.4.1.5.2SUBPART B
Subpart B - Pre-Installation Considerations
24:5.1.4.1.5.2.1.1SECTION 3285.101
   3285.101 Fire separation.
24:5.1.4.1.5.2.1.2SECTION 3285.102
   3285.102 Installation of manufactured homes in flood hazard areas.
24:5.1.4.1.5.2.1.3SECTION 3285.103
   3285.103 Site suitability with design zone maps.
24:5.1.4.1.5.2.1.4SECTION 3285.104
   3285.104 Moving manufactured home to location.
24:5.1.4.1.5.2.1.5SECTION 3285.105
   3285.105 Permits, other alterations, and on-site structures.
24:5.1.4.1.5.3SUBPART C
Subpart C - Site Preparation
24:5.1.4.1.5.3.1.1SECTION 3285.201
   3285.201 Soil conditions.
24:5.1.4.1.5.3.1.2SECTION 3285.202
   3285.202 Soil classifications and bearing capacity.
24:5.1.4.1.5.3.1.3SECTION 3285.203
   3285.203 Site Drainage.
24:5.1.4.1.5.3.1.4SECTION 3285.204
   3285.204 Ground moisture control.
24:5.1.4.1.5.4SUBPART D
Subpart D - Foundations
24:5.1.4.1.5.4.1.1SECTION 3285.301
   3285.301 General.
24:5.1.4.1.5.4.1.2SECTION 3285.302
   3285.302 Flood hazard areas.
24:5.1.4.1.5.4.1.3SECTION 3285.303
   3285.303 Piers.
24:5.1.4.1.5.4.1.4SECTION 3285.304
   3285.304 Pier configuration.
24:5.1.4.1.5.4.1.5SECTION 3285.305
   3285.305 Clearance under homes.
24:5.1.4.1.5.4.1.6SECTION 3285.306
   3285.306 Design procedures for concrete block piers.
24:5.1.4.1.5.4.1.7SECTION 3285.307
   3285.307 Perimeter support piers.
24:5.1.4.1.5.4.1.8SECTION 3285.308
   3285.308 Manufactured piers.
24:5.1.4.1.5.4.1.9SECTION 3285.309
   3285.309 [Reserved]
24:5.1.4.1.5.4.1.10SECTION 3285.310
   3285.310 Pier location and spacing.
24:5.1.4.1.5.4.1.11SECTION 3285.311
   3285.311 Required perimeter supports.
24:5.1.4.1.5.4.1.12SECTION 3285.312
   3285.312 Footings.
24:5.1.4.1.5.4.1.13SECTION 3285.313
   3285.313 Combination systems.
24:5.1.4.1.5.4.1.14SECTION 3285.314
   3285.314 [Reserved]
24:5.1.4.1.5.4.1.15SECTION 3285.315
   3285.315 Special snow load conditions.
24:5.1.4.1.5.5SUBPART E
Subpart E - Anchorage Against Wind
24:5.1.4.1.5.5.1.1SECTION 3285.401
   3285.401 Anchoring instructions.
24:5.1.4.1.5.5.1.2SECTION 3285.402
   3285.402 Ground anchor installations.
24:5.1.4.1.5.5.1.3SECTION 3285.403
   3285.403 Sidewall, over-the-roof, mate-line, and shear wall straps.
24:5.1.4.1.5.5.1.4SECTION 3285.404
   3285.404 Severe climatic conditions.
24:5.1.4.1.5.5.1.5SECTION 3285.405
   3285.405 Severe wind zones.
24:5.1.4.1.5.5.1.6SECTION 3285.406
   3285.406 Flood hazard areas.
24:5.1.4.1.5.6SUBPART F
Subpart F - Optional Features
24:5.1.4.1.5.6.1.1SECTION 3285.501
   3285.501 Home installation manual supplements.
24:5.1.4.1.5.6.1.2SECTION 3285.502
   3285.502 Expanding rooms.
24:5.1.4.1.5.6.1.3SECTION 3285.503
   3285.503 Optional appliances.
24:5.1.4.1.5.6.1.4SECTION 3285.504
   3285.504 Skirting.
24:5.1.4.1.5.6.1.5SECTION 3285.505
   3285.505 Crawlspace ventilation.
24:5.1.4.1.5.7SUBPART G
Subpart G - Ductwork and Plumbing and Fuel Supply Systems
24:5.1.4.1.5.7.1.1SECTION 3285.601
   3285.601 Field assembly.
24:5.1.4.1.5.7.1.2SECTION 3285.602
   3285.602 Utility connections.
24:5.1.4.1.5.7.1.3SECTION 3285.603
   3285.603 Water supply.
24:5.1.4.1.5.7.1.4SECTION 3285.604
   3285.604 Drainage system.
24:5.1.4.1.5.7.1.5SECTION 3285.605
   3285.605 Fuel supply system.
24:5.1.4.1.5.7.1.6SECTION 3285.606
   3285.606 Ductwork connections.
24:5.1.4.1.5.8SUBPART H
Subpart H - Electrical Systems and Equipment
24:5.1.4.1.5.8.1.1SECTION 3285.701
   3285.701 Electrical crossovers.
24:5.1.4.1.5.8.1.2SECTION 3285.702
   3285.702 Miscellaneous lights and fixtures.
24:5.1.4.1.5.8.1.3SECTION 3285.703
   3285.703 Smoke alarms.
24:5.1.4.1.5.8.1.4SECTION 3285.704
   3285.704 Telephone and cable TV.
24:5.1.4.1.5.9SUBPART I
Subpart I - Exterior and Interior Close-Up
24:5.1.4.1.5.9.1.1SECTION 3285.801
   3285.801 Exterior close-up.
24:5.1.4.1.5.9.1.2SECTION 3285.802
   3285.802 Structural interconnection of multi-section homes.
24:5.1.4.1.5.9.1.3SECTION 3285.803
   3285.803 Interior close-up.
24:5.1.4.1.5.9.1.4SECTION 3285.804
   3285.804 Bottom board repair.
24:5.1.4.1.5.10SUBPART J
Subpart J - Optional Information for Manufacturer's Installation Instructions
24:5.1.4.1.5.10.1.1SECTION 3285.901
   3285.901 General.
24:5.1.4.1.5.10.1.2SECTION 3285.902
   3285.902 Moving manufactured home to location.
24:5.1.4.1.5.10.1.3SECTION 3285.903
   3285.903 Permits, alterations, and on-site structures.
24:5.1.4.1.5.10.1.4SECTION 3285.904
   3285.904 Utility system connections.
24:5.1.4.1.5.10.1.5SECTION 3285.905
   3285.905 Heating oil systems.
24:5.1.4.1.5.10.1.6SECTION 3285.906
   3285.906 Telephone and cable TV.
24:5.1.4.1.5.10.1.7SECTION 3285.907
   3285.907 Manufacturer additions to installation instructions.