Title 14
SECTION 29.1549
29.1549 Powerplant instruments.
§ 29.1549 Powerplant instruments.For each required powerplant instrument, as appropriate to the type of instruments -
(a) Each maximum and, if applicable, minimum safe operating limit must be marked with a red radial or a red line;
(b) Each normal operating range must be marked with a green arc or green line, not extending beyond the maximum and minimum safe limits;
(c) Each takeoff and precautionary range must be marked with a yellow arc or yellow line;
(d) Each engine or propeller range that is restricted because of excessive vibration stresses must be marked with red arcs or red lines; and
(e) Each OEI limit or approved operating range must be marked to be clearly differentiated from the markings of paragraphs (a) through (d) of this section except that no marking is normally required for the 30-second OEI limit.
[Amdt. 29-12, 41 FR 55474, Dec. 20, 1976, as amended by Amdt. 29-26, 53 FR 34220, Sept. 2, 1988; Amdt. 29-34, 59 FR 47769, Sept. 16, 1994]