Title 14
SECTION 25.1395
25.1395 Maximum intensities in overlapping beams of forward and rear position lights.
§ 25.1395 Maximum intensities in overlapping beams of forward and rear position lights.No position light intensity may exceed the applicable values in the following table, except as provided in § 25.1389(b)(3).
Overlaps | Maximum intensity | |
---|---|---|
Area A (candles) | Area B (candles) | |
Green in dihedral angle L | 10 | 1 |
Red in dihedral angle R | 10 | 1 |
Green in dihedral angle A | 5 | 1 |
Red in dihedral angle A | 5 | 1 |
Rear white in dihedral angle L | 5 | 1 |
Rear white in dihedral angle R | 5 | 1 |
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.