This appendix specifies the HIRF environments and equipment HIRF test levels for electrical and electronic systems under § 25.1317. The field strength values for the HIRF environments and equipment HIRF test levels are expressed in root-mean-square units measured during the peak of the modulation cycle.

(a) HIRF environment I is specified in the following table:

Table I. - HIRF Environment I

Frequency Field strength
(volts/meter)
Peak Average
10 kHz-2 MHz 50 50
2 MHz-30 MHz 100 100
30 MHz-100 MHz 50 50
100 MHz-400 MHz 100 100
400 MHz-700 MHz 700 50
700 MHz-1 GHz 700 100
1 GHz-2 GHz 2,000 200
2 GHz-6 GHz 3,000 200
6 GHz-8 GHz 1,000 200
8 GHz-12 GHz 3,000 300
12 GHz-18 GHz 2,000 200
18 GHz-40 GHz 600 200