Appendix V1 to Subpart B of Part 430 - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits Packaged With Other Fluorescent Lamps (not Compact Fluorescent Lamps or General Service Fluorescent Lamps), Packaged With Other SSL Lamps (not Integrated LED Lamps), or With Integrated SSL Circuitry
10:3.0.1.4.18.3.13.6.33 : Appendix V1
Appendix V1 to Subpart B of Part 430 - Uniform Test Method for
Measuring the Energy Consumption of Ceiling Fan Light Kits Packaged
With Other Fluorescent Lamps (not Compact Fluorescent Lamps or
General Service Fluorescent Lamps), Packaged With Other SSL Lamps
(not Integrated LED Lamps), or With Integrated SSL Circuitry Note:
Any representations about the energy use or efficiency of any
ceiling fan light kit packaged with fluorescent lamps other than
compact fluorescent lamps or general service fluorescent lamps,
packaged with SSL products other than integrated LED lamps, or with
integrated SSL circuitry made on or after the compliance date of
any amended energy conservation standards must be based on testing
pursuant to this appendix. Manufacturers may make representations
based on testing in accordance with this appendix prior to the
compliance date of any amended energy conservation standards,
provided that such representations demonstrate compliance with the
amended energy conservation standards.
1. Scope: This appendix establishes the test requirements
to measure the energy efficiency of all ceiling fan light kits
(CFLKs) packaged with fluorescent lamps other than compact
fluorescent lamps or general service fluorescent lamps, packaged
with SSL products other than integrated LED lamps, or with
integrated SSL circuitry.
2. Definitions
2.1. CFLK with integrated SSL circuitry means a CFLK that
has SSL light sources, drivers, heat sinks, or intermediate
circuitry (such as wiring between a replaceable driver and a
replaceable light source) that are not consumer replaceable.
2.2. Covers means materials used to diffuse or redirect
light produced by an SSL light source in CFLKs with integrated SSL
circuitry.
2.3. Other (non-CFL and non-GSFL) fluorescent lamp means
a low-pressure mercury electric-discharge lamp in which a
fluorescing coating transforms some of the ultraviolet energy
generated by the mercury discharge into light, including but not
limited to circline fluorescent lamps, and excluding any compact
fluorescent lamp and any general service fluorescent lamp.
2.4. Other SSL products means an integrated unit
consisting of a light source, driver, heat sink, and intermediate
circuitry that uses SSL technology (such as light-emitting diodes
or organic light-emitting diodes) and is consumer replaceable in a
CFLK. The term does not include LED lamps with ANSI-standard bases.
Examples of other SSL products include OLED lamps, LED lamps with
non-ANSI-standard bases, such as Zhaga interfaces, and LED light
engines.
2.5. Solid-State Lighting (SSL) means technology where
light is emitted from a solid object - a block of semiconductor -
rather than from a filament or plasma, as in the case of
incandescent and fluorescent lighting. This includes inorganic
light-emitting diodes (LEDs) and organic light-emitting diodes
(OLEDs).
3. Test Conditions and Measurements
For any CFLK that utilizes consumer replaceable lamps, measure
the lamp efficacy of each basic model of lamp packaged with the
CFLK. For any CFLK only with integrated SSL circuitry, measure the
luminaire efficacy of the CFLK. For any CFLK that includes both
consumer replaceable lamps and integrated SSL circuitry, measure
both the lamp efficacy of each basic model of lamp packaged with
the CFLK and the luminaire efficacy of the CFLK with all consumer
replaceable lamps removed. Take measurements at full light output.
Do not use a goniophotometer. For each test, use the test
procedures in the table below. CFLKs with integrated SSL circuitry
and consumer replaceable covers may be measured with their covers
removed but must otherwise be measured according to the table
below.
Lighting technology |
Lamp or luminaire efficacy
measured |
Referenced test
procedure |
Other (non-CFL and
non-GSFL) fluorescent lamps |
Lamp Efficacy |
IES LM-9-09, sections
4-7.* |
Other SSL
products |
Lamp Efficacy |
IES LM-79-08, sections
2-9.2.* |
CFLKs with
integrated SSL circuitry |
Luminaire Efficacy |
IES LM-79-08, sections
2-9.2. |
[80 FR 80227, Dec. 24, 2015]