Appendix V to Subpart B of Part 430 - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits With Pin-Based Sockets for Fluorescent Lamps
10:3.0.1.4.18.3.13.6.32 : Appendix V
Appendix V to Subpart B of Part 430 - Uniform Test Method for
Measuring the Energy Consumption of Ceiling Fan Light Kits With
Pin-Based Sockets for Fluorescent Lamps
Prior to June 21, 2016, manufacturers must make any
representations with respect to the energy use or efficiency of
ceiling fan light kits with pin-based sockets for fluorescent lamps
in accordance with the results of testing pursuant to this Appendix
V or the procedures in Appendix V as it appeared at 10 CFR part
430, subpart B, Appendix V, in the 10 CFR parts 200 to 499 edition
revised as of January 1, 2015. On or after June 21, 2016,
manufacturers must make any representations with respect to energy
use or efficiency of ceiling fan light kits with pin-based sockets
for fluorescent lamps in accordance with the results of testing
pursuant to this appendix to demonstrate compliance with the energy
conservation standards at 10 CFR 430.32(s)(3).
Alternatively, manufacturers may make representations based on
testing in accordance with appendix V1 to this subpart, provided
that such representations demonstrate compliance with the amended
energy conservation standards. Manufacturers must make all
representations with respect to energy use or efficiency in
accordance with whichever version is selected for testing.
1. Scope: This appendix contains test requirements to
measure the energy performance of ceiling fan light kits (CFLKs)
with pin-based sockets that are packaged with fluorescent
lamps.
2. Definitions
2.1. Input power means the measured total power used by
all lamp(s) and ballast(s) of the CFLK during operation, expressed
in watts (W) and measured using the lamp and ballast packaged with
the CFLK.
2.2. Lamp ballast platform means a pairing of one ballast
with one or more lamps that can operate simultaneously on that
ballast. Each unique combination of manufacturer, basic model
numbers of the ballast and lamp(s), and the quantity of lamps that
operate on the ballast, corresponds to a unique platform.
2.3. Lamp lumens means a measurement of lumen output or
luminous flux measured using the lamps and ballasts shipped with
the CFLK, expressed in lumens.
2.4. System efficacy means the ratio of measured lamp
lumens to measured input power, expressed in lumens per watt, and
is determined for each unique lamp ballast platform packaged with
the CFLK.
3. Test Apparatus and General Instructions:
The test apparatus and instructions for testing pin-based
fluorescent lamps packaged with ceiling fan light kits that have
pin-based sockets must conform to the following requirements:
Any lamp
satisfying this description: |
must be tested on the lamp
ballast platform packaged with the CFLK in accordance with the
requirements of: |
Compact
fluorescent lamp |
sections 4-6 of IES LM-66-14
(incorporated by reference, see § 430.3) |
Any other
fluorescent lamp |
sections 4-7 of IES LM-9-09
(incorporated by reference, see § 430.3) |
4. Test Measurement and Calculations:
Measure system efficacy as follows and express the result in
lumens per watt:
Lamp type |
Method |
Compact
fluorescent lamp |
Measure system efficacy
according to section 6 of IES LM-66-14 (incorporated by reference;
see § 430.3). Use of a goniophotometer is not permitted. |
Any other
fluorescent lamp |
Measure system efficacy
according to section 7 of IES LM-9-09 (incorporated by reference;
see § 430.3). Use of a goniophotometer is not permitted. |
[80 FR 80226, Dec. 24, 2015]