Title 46

SECTION 131.550

131.550 Maintenance of falls.

§ 131.550 Maintenance of falls.

(a) Each fall used with a launching appliance must be turned end for end at intervals of not more than 30 months.

(b) Each fall used with a launching appliance must be renewed either when necessary because of deterioration or after the passage of not more than 5 years, whichever occurs earlier.

(c) Each fall used with a launching appliance must have a corrosion-resistant tag permanently marked with -

(1) The date the new fall was installed; and

(2) The last date, if any, the fall was turned end for end.