§ 60.4335a How do I demonstrate compliance with my NO<sub>X</sub> emissions standard without using a NO<sub>X</sub> CEMS if I use water or steam injection?

40 CFR 60.4335a

Citation40 CFR 60.4335a
CorpusDaily eCFR
Displayed edition2026-04-24
Last updated2026-04-24

§ 60.4335a How do I demonstrate compliance with my NOX emissions standard without using a NOX CEMS if I use water or steam injection?

If you qualify and elect to demonstrate continuous compliance according to the provisions of § 60.4333a(c)(1), you must install, calibrate, maintain, and operate a continuous monitoring system to monitor and record the fuel consumption and the water or steam to fuel ratio fired in the combustion turbine engine consistent with the requirements in § 60.4342a. Water or steam only needs to be injected when a fuel is being combusted that requires water or steam injection for compliance with the applicable NOX emissions standard.

Authority42 U.S.C. 7401 et seq.
Source36 FR 24877, Dec. 23, 1971, unless otherwise noted.