Title 40

SECTION 466.32

466.32 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

§ 466.32 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

Subpart C - BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
Metal preparation Coating operation Metal preparation Coating operation
Metric units - mg/m 2 of area processed or coated
Chromium 16.34 0.53 6.62 0.22
Lead 5.84 0.19 5.06 0.16
Nickel 54.85 1.78 38.90 1.26
Zinc 51.74 1.68 21.79 1.71
Aluminum 176.98 5.74 72.35 2.35
Iron 47.85 1.55 24.51 0.80
English units - pounds per 1 million ft 2 of area processed or coated
Chromium 3.35 0.11 1.36 0.05
Lead 1.20 0.04 1.04 0.03
Nickel 11.24 0.37 7.97 0.26
Zinc 10.60 0.35 4.46 0.35
Aluminum 36.25 1.18 14.82 0.48
Iron 9.80 0.32 5.02 0.16
[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36544, Sept. 6, 1985]