Title 40

SECTION 429.31

429.31 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

§ 429.31 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by application of the best practicable control technology currently available (BPT):

(a) The following limitations constitute the maximum permissible discharge for all veneer manufacturing installations other than those referred to in paragraphs (b) and (c) of this section: There shall be no discharge of process wastewater pollutants into navigable waters.

(b) The following limitations constitute the maximum permissible discharge for softwood veneer manufacturing processes which use direct steaming for the conditioning of logs:

Subpart B

Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per cubic meter of production)
BOD5 0.72 0.24
pH ( 1) ( 1)
English units (pounds per cubic foot of production)
BOD5 0.045 0.015
pH ( 1) ( 1)

1 Within the range 6.0 to 9.0 at all times.

(c) The following limitations constitute the maximum permissible discharge for hardwood veneer manufacturing processes which use direct steaming for the conditioning of logs:

Subpart B

Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per cubic meter of production)
BOD5 1.62 0.54
pH ( 1) ( 1)
English units (pounds per cubic foot of production)
BOD5 0.10 0.034
pH ( 1) ( 1)

1 Within the range 6.0 to 9.0 at all times.