Title 40

SECTION 409.42

409.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

§ 409.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributable to the barometric condenser cooling water to that amount of BOD5 attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed -
Metric units (kg/kkg of gross cane)
BOD5 1.14 0.63
TSS 1.41 0.47
pH ( 1) ( 1)
English units (lb/1,000 lb of gross cane)
BOD5 1.14 0.63
TSS 1.41 0.47
pH ( 1) ( 1)

1 Within the range 6.0 to 9.0.

(b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributable to the barometric condenser cooling water to that amount of BOD5 attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.

Effluent characteristic Effluent limitations, the total of the daily values for the entire discharge period shall not exceed -
Metric units (kg/kkg of gross cane)
BOD5 0.63.
TSS 0.47.
pH Within the range 6.0 to 9.0.
English units (lb/1,000 lb of gross cane)
BOD5 0.63.
TSS 0.47.
pH Within the range 6.0 to 9.0.
[40 FR 8503, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]