Title 40
PART 65 APPENDIX
A. 40 CFR part 60, subpart A provisions for referencing subparts Ka, Kb, VV, DDD, III, NNN, and RRR |
§ 60.1, |
§ 60.2, |
§ 60.5, |
§ 60.6, |
§ 60.7(a)(1), and (a)(4), |
§ 60.14, |
§ 60.15, |
§ 60.16 |
B. 40 CFR part 61, subpart A provisions for referencing subparts Y, V, and BB |
§ 61.01, |
§ 61.02, |
§ 61.05, |
§ 61.06, |
§ 61.07, |
§ 61.08, |
§ 61.10(b), and (c), |
§ 61.11, § 61.15 |
C. 40 CFR part 63, subpart A provisions for referencing subparts G and H |
§ 63.1(a)(1), (a)(2), (a)(3), (a)(13), (a)(14), (b)(2) and (c)(4) |
§ 63.2 |
§ 63.5 (a)(1), (a)(2), (b), (d)(1)(ii), (d)(3)(i), a (d)(3)(iii), a (d)(3)(iv), a (d)(3)(v), a (d)(3)(vi), a (d)(4), (e), (f)(1), and (f)(2) |
§ 63.6 (a), (b)(3), (c)(5), (i)(1), (i)(2), (i)(4)(i)(A), (i)(5) through (i)(14), (i)(16) and (j) |
§ 63.9(a)(2), (b)(4)(i), b (b)(4)(ii), (b)(4)(iii), (b)(5), b (c) and (d) |
§ 63.10(d)(4) |
§ 63.12(b) |
a These provisions do not apply to equipment leaks.
b The notifications specified in 40 CFR 63.9(b)(4)(i) and 63.9(b)(5) shall be submitted at the times specified in this part 65.
Table 2 to Subpart A of Part 65 - Applicable Referencing Subpart Provisions
40:17.0.1.1.2.1.1.16.2 :
Table 2 to Subpart A of Part 65 - Applicable Referencing Subpart ProvisionsIf you have been
referenced from * * * |
You must comply with * * * |
---|---|
40 CFR part 60, subpart Ka | 60.110a, 60.111a, and 60.115a |
40 CFR part 60, subpart Kb | 60.110b, 60.111b, 60.116b(c), (e), (f)(1), and (g) |
40 CFR part 60, subpart VV | 60.480, 60.481, 60.482-1(a), 60.485(d), (e), and (f), and 60.486(i) and (j), 60.488, and 60.489 |
40 CFR part 60, subpart DDD | 60.560(a), (b) and (d) through (j), 60.561, 60.562-1, 60.562-2, and 60.565(g)(1) |
40 CFR part 60, subpart III | 60.610(a), (b) and (d), 60.611, 60.616, 60.617 |
40 CFR part 60, subpart NNN | 60.660(a), (b), (c)(1) through (c)(3), (c)(5), (d), 60.661, 60.666, and 60.667 |
40 CFR part 60, subpart RRR | 60.700(a), (b), (c)(1), (c)(3), (c)(5), (c)(6), (c)(7), (d), 60.701, 60.706, 60.707 |
40 CFR part 61, subpart V | 61.240, 61.241, 61.245(d), 61.246(i) and (j), and 61.247(a) and (f) |
40 CFR part 61, subpart Y | 61.270, 61.271(d)(2), and 61.274(a) |
40 CFR part 61, subpart BB | 61.300 and 61.301 |
40 CFR part 63, subpart G For process vents, group 1 storage vessels, and group 1 transfer racks | 63.100, 63.101, 63.104 and 63.105 of subpart F and 63.110 and 63.111 of subpart G |
40 CFR part 63, subpart H | 63.100, 63.101, 63.104 and 63.105 of subpart F, and 63.160, 63.161, 63.180(d) of subpart H |
Table 3 to Subpart A of Part 65 - Detection Sensitivity Levels (grams per hour)
40:17.0.1.1.2.1.1.16.3 :
Table 3 to Subpart A of Part 65 - Detection Sensitivity Levels (grams per hour)Monitoring Frequency per Subpart a | Detection Sensitivity Level |
---|---|
Bi-Monthly | 60 |
Semi-Quarterly | 85 |
Monthly | 100 |
a When this alternative work practice is used to identify leaking equipment, the owner or operator must choose one of the monitoring frequencies listed in this table, in lieu of the monitoring frequency specified in the applicable subpart. Bi-monthly means every other month. Semi-quarterly means twice per quarter. Monthly means once per month.
Table 1 to Subpart D of Part 65 - Concentration for Group Determination
40:17.0.1.1.2.4.1.10.4 :
Table 1 to Subpart D of Part 65 - Concentration for Group DeterminationReferencing subpart | Concentration 1 |
---|---|
Subpart III of Part 60 | NA. |
Subpart NNN of Part 60 | 300 ppmv of TOC. |
Subpart RRR of Part 60 | 300 ppmv of TOC. |
Subpart G of Part 63 | 50 ppmv of HAP 2. |
1 The 50 ppm HAP concentration cutoff only applies to 40 CFR part 63, subpart G sources. Process vents subject to only 40 CFR part 60, subparts RRR or NNN are eligible for the 300 ppm TOC cutoff. There is no concentration cutoff for subpart III sources. The process vent provisions of subpart DDD are not consolidated under this subpart.
2 For process vents subject to subpart G of 40 CFR part 63, the owner or operator may measure HAP or TOC concentration with regard to the low concentration exemption provisions of this part.
Table 2 to Subpart D of Part 65 - TRE Parameters for NSPS Referencing Subparts a
40:17.0.1.1.2.4.1.10.5 :
Table 2 to Subpart D of Part 65 - TRE Parameters for NSPS Referencing Subparts aHalogenated vent stream? | Net heating
value (MJ/scm) b |
Vent stream flow rate (scm/min) c | Values of terms for TRE equation: TRE = A * [ B + C + D + E + F ] | Equation number | |||||
---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | F | ||||
Yes | 0≤H ≤3.5 | Q <14.2 | 1/ETOC | 30.96334 | 0 | 0 | −0.13064QH | 0 | 1 |
14.2≤Q ≤18.8 | 1/ETOC | 19.18370 | 0.27580Q | 0.757620Q 0.88 | −0.13064QH | 0.01025Q 0.5 | 2 | ||
18.8<Q ≤699 | 1/ETOC | 20.00563 | 0.27580Q | 0.303870Q 0.88 | −0.13064QH | 0.01025Q 0.5 | 3 | ||
699<Q ≤1400 | 1/ETOC | 39.87022 | 0.29973Q | 0.303870Q 0.88 | −0.13064QH | 0.01449Q 0.5 | 4 | ||
1400<Q ≤2100 | 1/ETOC | 59.73481 | 0.31467Q | 0.303870Q 0.88 | −0.13064QH | 0.01775Q 0.5 | 5 | ||
2100<Q ≤2800 | 1/ETOC | 79.59941 | 0.32572Q | 0.303870Q 0.88 | −0.13064QH | 0.02049Q 0.5 | 6 | ||
2800<Q ≤3500 | 1/ETOC | 99.46400 | 0.33456Q | 0.303870Q 0.88 | −0.13064QH | 0.02291Q 0.5 | 7 | ||
H >3.5 | Q <14.2 | 1/ETOC | 20.61052 | 0 | 0 | 0 | 0 | 8 | |
14.2≤Q ≤18.8 | 1/ETOC | 18.84466 | 0.26742Q | −0.200440Q 0.88 | 0 | 0.01025Q 0.5 | 9 | ||
18.8<Q ≤699 | 1/ETOC | 19.66658 | 0.26742Q | −0.253320Q 0.88 | 0 | 0.01025Q 0.5 | 10 | ||
699<Q ≤1400 | 1/ETOC | 39.19213 | 0.29062Q | −0.253320Q 0.88 | 0 | 0.01449Q 0.5 | 11 | ||
1400<Q ≤2100 | 1/ETOC | 58.71768 | 0.30511Q | −0.253320Q 0.88 | 0 | 0.01775Q 0.5 | 12 | ||
2100<Q ≤2800 | 1/ETOC | 78.24323 | 0.31582Q | −0.253320Q 0.88 | 0 | 0.02049Q 0.5 | 13 | ||
2800<Q ≤3500 | 1/ETOC | 97.76879 | 0.32439Q | −0.253320Q 0.88 | 0 | 0.02291Q 0.5 | 14 | ||
No | 0≤H ≤0.48 | Q <14.2 | 1/ETOC | 11.01250 | 0 | 0 | −0.17109QH | 0 | 15 |
14.2≤Q ≤1340 | 1/ETOC | 8.54245 | 0.10555Q | 0.090300Q 0.88 | −0.17109QH | 0.01025Q 0.5 | 16 | ||
1340<Q ≤2690 | 1/ETOC | 16.94386 | 0.11470Q | 0.090300Q 0.88 | −0.17109QH | 0.01449Q 0.5 | 17 | ||
2690<Q ≤4040 | 1/ETOC | 25.34528 | 0.12042Q | 0.090300Q 0.88 | −0.17109QH | 0.01775Q 0.5 | 18 | ||
0.48<H ≤1.9 | Q <14.2 | 1/ETOC | 13.45630 | 0 | 0 | −0.16181QH | 0 | 19 | |
14.2≤Q ≤1340 | 1/ETOC | 9.25233 | 0.06105Q | 0.319370Q 0.88 | −0.16181QH1 | 0.01025Q 0.5 | 20 | ||
1340<Q ≤2690 | 1/ETOC | 18.36363 | 0.06635Q | 0.319370Q 0.88 | −0.16181QH | 0.01449Q 0.5 | 21 | ||
2690<Q ≤4040 | 1/ETOC | 27.47492 | 0.06965Q | 0.319370Q 0.88 | −0.16181QH | 0.01775Q 0.5 | 22 | ||
1.9<H ≤3.6 | Q <14.2 | 1/ETOC | 7.96988 | 0 | 0 | 0 | 0 | 23 | |
14.2≤Q ≤1180 | 1/ETOC | 6.67868 | 0.06943Q | 0.025820Q 0.88 | 0 | 0.01025Q 0.5 | 24 | ||
1180<Q ≤2370 | 1/ETOC | 13.21633 | 0.07546Q | 0.025820Q 0.88 | 0 | 0.01449Q 0.5 | 25 | ||
2370<Q ≤3550 | 1/ETOC | 19.75398 | 0.07922Q | 0.025820Q 0.88 | 0 | 0.01775Q 0.5 | 26 | ||
H >3.6 | Q <14.2 | 1/ETOC | 6.67868 | 0 | 0.02220Q 0.88H 0.88 | −0.00707QH | 0.02036H 0.5 | 27 | |
Q ≥14.2 and 14.2≤Q*(H/3.6) ≤1180 |
1/ETOC | 6.67868 | 0 | 0.02220Q 0.88H 0.88 | −0.00707QH | 0.00540Q 0.5H 0.5 | 28 | ||
Q ≥14.2 and 1180<Q*(H/3.6) ≤2370 |
1/ETOC | 13.21633 | 0 | 0.02412Q 0.88H 0.88 | −0.00707QH | 0.00764Q 0.5H 0.5 | 29 | ||
Q ≥14.2 and 2370<Q*(H/3.6) ≤3550 |
1/ETOC | 19.75398 | 0 | 0.02533Q 0.88H 0.88 | −0.00707QH | 0.00936Q 0.5H 0.5 | 30 | ||
No | 0≤H <11.2 | All | 1/ETOC | 2.08 | 2.25Q | 0.288Q 0.8 | −0.193QH | −0.0051ETOC | 31 |
H ≥11.2 | All | 1/ETOC | 2.08 | 0.309Q | 0.0619Q 0.8 | −0.0043QH | −0.0043ETOC | 32 |
a Use according to procedures outlined in § 65.64(h).
b MJ/scm = mega Joules per standard cubic meter.
c scm/min = standard cubic meters per minute.
Table 3 to Subpart D of Part 65 - TRE Parameters for HON Referencing Subparts a
40:17.0.1.1.2.4.1.10.6 :
Table 3 to Subpart D of Part 65 - TRE Parameters for HON Referencing Subparts aExisting or new? | Halogenated vent stream? | Values of terms for TRE equation: TRE = A * [ B + C + D + E + F ] | ||||||
---|---|---|---|---|---|---|---|---|
A | B | C | D | E | F | Equation number | ||
Existing | Yes | 1/EHAP | 3.995 | 0.05200Q | 0 | −0.001769H | 0.0009700ETOC | 33 |
No | 1/EHAP | 1.935 | 0.3660Q | 0 | −0.007687H | −0.000733ETOC | 34 | |
1/EHAP | 1.492 | 0.06267Q | 0 | 0.03177H | −0.001159ETOC | 35 | ||
1/EHAP | 2.519 | 0.01183Q | 0 | 0.01300H | 0.04790ETOC | 36 | ||
New | Yes | 1/EHAP | 1.0895 | 0.01417Q | 0 | −0.000482H | 0.0002645ETOC | 37 |
No | 1/EHAP | 0.5276 | 0.0998Q | 0 | −0.002096H | −0.0002000ETOC | 38 | |
1/EHAP | 0.4068 | 0.0171Q | 0 | 0.008664H | −0.000316ETOC | 39 | ||
1/EHAP | 0.6868 | 0.00321Q | 0 | 0.003546H | 0.01306ETOC | 40 |
a Use according to procedures outlined in § 65.64(h).
Table 1 to Subpart F of Part 65 - Batch Processes Monitoring Frequency for Equipment Other Than Connectors
40:17.0.1.1.2.6.1.23.7 :
Table 1 to Subpart F of Part 65 - Batch Processes Monitoring Frequency for Equipment Other Than ConnectorsOperating
time (percent of year) |
Equivalent continuous process monitoring frequency time in use | ||
---|---|---|---|
Monthly | Quarterly | Semiannually | |
0 to <25 | Quarterly | Annually | Annually. |
25 to <50 | Quarterly | Semiannually | Annually. |
50 to <75 | Bimonthly | Three times | Semiannually. |
75 to 100 | Monthly | Quarterly | Semiannually. |