Table 3 to Subpart WWWW of Part 60—Model Rule—Emission Limits for Existing Large Municipal Waste Combustors
| For the air pollutant . . . | For this combustor type . . . | You must meet this emission limit, corrected to 7 percent oxygen a . . . |
|---|---|---|
| Particulate matter | All | 20 mg/dscm. |
| Opacity | All | 10 percent opacity (6-minute block average). |
| Cadmium | All | 10 ug/dscm. |
| Lead | All | 68 ug/dscm. |
| Mercury | All | 50 ug/dscm or 85 percent reduction by weight. |
| Sulfur dioxide | All | 22 parts per million by volume dry basis or 75 percent reduction by weight or volume (daily 24-hr geometric average). |
| Nitrogen oxide b | Mass burn waterwall | 205 parts per million by volume dry basis (daily 24-hr arithmetic average). |
| Mass burn rotary | 150 parts per million by volume dry basis (daily 24-hr arithmetic average). | |
| Refuse-derived fuel stoker | 160 parts per million by volume dry basis (daily 24-hr arithmetic average). | |
| Refuse-derived fuel spreader stoker and semi-suspension | 160 parts per million by volume dry basis (daily 24-hr arithmetic average). | |
| Refuse-derived fuel fluidized bed | 180 parts per million by volume dry basis (daily 24-hr arithmetic average). | |
| Hydrogen chloride | All | 10 parts per million by volume dry basis or 96 percent reduction by weight or volume. |
| Dioxins/furans | All | 14 nanograms per dry standard cubic meter (total mass). |
| a CEMS data during warmup, startup, and shutdown, as defined in this subpart, are not corrected to 7 percent oxygen and are used as measured. | ||
| b Existing mass burn waterwall units equipped with air-to-air heat exchanger flue gas reheat in advance of a selective catalytic reduction control device are subject to a 50 parts per million by volume dry basis emission limit. |