Title 10
SECTION 429.15
429.15 Room air conditioners.
§ 429.15 Room air conditioners.(a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to room air conditioners; and
(2) For each basic model of room air conditioners, a sample of sufficient size shall be randomly selected and tested to ensure that -
(i) Any represented value of estimated annual operating cost, energy consumption or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(A) The mean of the sample, where:
or,(B) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:
and(ii) Any represented value of the energy efficiency ratio or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(A) The mean of the sample, where:
or,(B) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:
(b) Certification reports. (1) The requirements of § 429.12 are applicable to room air conditioners; and
(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/W-h)), cooling capacity in British thermal units per hour (Btu/h), and the electrical power input in watts (W).
[76 FR 12451, Mar. 7, 2011; 76 FR 24763, May 2, 2011]