Each RCRS transmitter type must be designed to satisfy the applicable unwanted emissions limits in this paragraph.

(a) 26-28 MHz frequency band. For an RCRS transmitter operating in the 26-28 MHz frequency band, the power of unwanted emissions must be attenuated below the transmitter output power in Watts (P) by at least:

(1) 25 dB (decibels) in the frequency band 4 kHz to 8 kHz removed from the channel center frequency;

(2) 35 dB in the frequency band 8 kHz to 20 kHz removed from the channel center frequency;

(3) 43 + 10 log (P) dB in any frequency band removed from the channel center frequency by more than 20 kHz.

(b) 72 and 75 MHz frequency bands. For an RCRS transmitter operating in the 72 and/or 75 MHz frequency bands, the power of unwanted emissions must be attenuated below the transmitter output power in Watts (P) by at least:

(1) 25 dB (decibels) in the frequency band 4 kHz to 8 kHz removed from the channel center frequency;

(2) 45 dB in the frequency band 8 kHz to 10 kHz removed from the channel center frequency;

(3) 55 dB in the frequency band 10 kHz to 20 kHz removed from the channel center frequency; and

(4) 56 + 10 log (P) dB in any frequency band removed from the channel center frequency by more than 20 kHz.

(c) Measurement bandwidths. The power of unwanted emissions in the frequency bands specified in paragraphs (a)(1) and (2) and (b)(1) through (3) of this section is measured with a reference bandwidth of 300 Hz. The power of unwanted emissions in the frequency ranges specified in paragraphs (a)(3) and (b)(4) of this section is measured with a reference bandwidth of at least 30 kHz.